Leave Your Message

DFW Switched Cable Branch Box - Reliable Power Solutions from China Suppliers & Factory

,

Advanced Functional Characteristics

,

Introducing our state-of-the-art prefabricated silicone rubber cable terminals, designed with touchable functionality that ensures full sealing, insulation, and maintenance-free operation for enhanced personal safety. Our compact and visually appealing product features a durable double-layer stainless steel body, engineered to last over twenty years.

,

This innovative design allows for regional power outage maintenance without disrupting the main network's operation, significantly minimizing the impact of power outages. Our system can accommodate one or multiple SF6 Load Switches, offering flexible and diverse wiring methods with branch outgoing lines supporting up to 8 circuits.

,

As a leading China supplier, we provide optional components, including surge protectors, short-circuit fault indicators, and current-limiting fuses, tailored to meet diverse user requirements. Partner with us for robust solutions from a trusted factory that prioritizes quality and reliability.

,

    Model and Definitions

    product-description1

    DFW Technical Parameters

    No. Items Parameters
    1 Nominal Voltage 12kV
    2 Rated Currency 630A
    3 Power Frequency Withstand Voltage (Phase to Ground) 42kV/min
    4 Lightning lmpulse Voltage 75kV
    5 Rated Breaking Current 630A
    6 Rated Short-circuit Making Current(Peak Value) 50kA
    7 Rated Short-time Withstand Current 25kA/4S
    8 Rated Peak Withstand Current 50kA
    9 Rated Peak Withstand Current 45A
    10 Rated Breaking Capacitive Current 16A
    11 Full Load Breaking Time >100
    12 Mechanical Operation Time for Opening and Closing 2000

    External Schematic Diagram

    product-description2

    Basic Structure

    product-description3
    product-description4

    Technical Requirements

    • The inner side of the brick wall is to be sealed with a 1:3 cement mortar mix and treated for waterproofing.
    • Beam penetrations should use φ6 concrete operations.
    • The foundation channel steel must undergo anti-corrosion treatment after fabrication.
    • After the installation of the branch box is completed, the area around the base should be sealed with cement.
    • Waterproof measures must be taken at the manhole entrance.
    • Grounding electrodes should be pre-embedded in the foundation, with grounding resistance meeting the requirements set by the power department.

    Ordering Instructions

    • The product model and any special requirements from the user can provide a one-time diagram.
    • The standard cross-sections for incoming and outgoing lines and branch cables.
    • The quantity of optional surge protectors and short-circuit fault indicators.

    Frequently Asked Questions

    Q What is the nominal voltage and rated current of the DFW cable branch box?
    The nominal voltage is 12kV, and the rated current is 630A.
    Q What are the waterproofing requirements for the foundation installation?
    The inner side of the brick wall must be sealed with a 1:3 cement mortar mix and waterproofed. Additionally, waterproof measures must be taken at the manhole entrance, and the area around the base should be sealed with cement after installation.
    Q What is the mechanical operation life of this equipment?
    The mechanical operation time for opening and closing is rated at 2000 times.
    Q What information should be provided when placing an order?
    You should specify the product model, any special user requirements, the standard cross-sections for incoming/outgoing lines and branch cables, and the required quantity of optional surge protectors and short-circuit fault indicators.
    Q What are the grounding requirements for the DFW installation?
    Grounding electrodes must be pre-embedded in the foundation, and the grounding resistance must meet the specific requirements set by the power department.
    Q What are the rated short-circuit making and short-time withstand currents?
    The rated short-circuit making current (peak value) is 50kA, and the rated short-time withstand current is 25kA/4S.