China ZGS11-12 Combined American Prefabricated Substation - Reliable Suppliers and Factory Solutions
Model meaning
Conditions of Use
- ◇ Altitude not exceeding 1000m;
- ◇ Ambient temperature: -35℃~+40℃;
- ◇ Relative humidity: daily average value is not more than 95%, monthly average value is not more than 90%;
- ◇ Installation location: A well-ventilated place without fire or explosion hazards, chemical corrosive gases, and a ground inclination of no more than 3 °.
Technical Parameters
| NO. | Name | Unit | Technical Parameters |
|---|---|---|---|
| 1 | Rated voltage | KV | 10/0.4(high pressure/1 low pressure) |
| 2 | Maximum operating voltage | KV | 12 (high voltage side) |
| 3 | Rated frequency | HZ | 50 |
| 4 | Rated capacity | KVA | 50-1600 |
| 5 | 1 minute power frequency withstand voltage | KV | 35 |
| 6 | Lightning impulse voltage | KV | 75 |
| 7 | Cooling method | - | Oil-immersed self-cooling |
| 8 | High voltage backup fuse breaking current | KA | 50 |
| 9 | Plug-in fuse breaking current | KA | 25 |
| 10 | Ambient temperature | - | -35~+40 |
| 11 | Coil allowable temperature rise | ℃ | 65 |
| 12 | No-load voltage regulation | ℃ | ±5%or±2×2.5% |
| 13 | Noise Level | db | 50 |
| 14 | Protection level | - | lp43 |
Installation Dimensions
Ordering Instructions
- ◇ Product operation location and special requirements;
- ◇ Provide product ordering drawings, which should include wiring diagrams, and should indicate transformer capacity, main component models and specifications, power distribution branch circuits and capacity;
- ◇ When electric energy metering and reactive power automatic compensation devices are required, the configuration requirements of the metering electric energy meter and mutual inductor shall be provided, and the capacity of the compensation capacitor shall be indicated;
- ◇ Indicate the requirements for product surface treatment;
- ◇ When ordering combined transformers, please specify terminal type or ring network type.
Examples of some product appearance drawings
Frequently Asked Questions (FAQ)
Q1: What is the rated capacity range for this combined transformer?
A1: The rated capacity for this series ranges from 50 KVA up to 1600 KVA, allowing it to adapt to various power distribution requirements.
Q2: What are the primary environmental requirements for installation?
A2: The unit should be installed at an altitude below 1000m, within an ambient temperature range of -35℃ to +40℃, and in a well-ventilated area with a ground inclination of no more than 3°. It must be free from fire, explosion, or chemical corrosive hazards.
Q3: What cooling method does this transformer utilize?
A3: The transformer utilizes an oil-immersed self-cooling method, which ensures efficient heat dissipation and stable operation under standard conditions.
Q4: What is the protection level and noise rating of this equipment?
A4: The transformer has a protection level rating of IP43 and operates at a quiet noise level of 50 dB.
Q5: What essential details must be provided when placing an order?
A5: You should provide the operation location, ordering drawings (including wiring diagrams, capacity, component models, and specifications), metering or compensation requirements, surface treatment requirements, and specify whether a terminal or ring network type is needed.