Introducing our triangle three-dimensional wound core dry-type power transformer, a state-of-the-art power transformation solution designed for ultimate efficiency. Utilizing air convection for natural cooling and optional fan-assisted cooling, this transformer operates without immersion in insulating liquid. With high insulation heat resistance and exceptional fire resistance, it is capable of meeting the demands of various applications. This transformer is ideal for power transmission and transformation systems, particularly in high-rise buildings, commercial centers, industrial and mining enterprises, oil platforms, subways, and tunnels. As a leading factory in China, we ensure top quality and reliability, making us one of the foremost suppliers in the industry.

,

    Model meaning

    product-description1
    Rated capacity (KVA) Voltage combination Connection Group Label No load Power consumption (W) Load loss group A (W) No load Current(%) Short circuit impedance (%) Sound Power class dB(A) Dimensions (mm (length, width and height) Installation 4φ18 Total weight (kg)
    high pressure (KV) Demarcation range Low pressure 100°C 100°C 100°C
    B(100°C) F(120°C) H(145°C)
    30 6
    6.3
    6.6
    10
    10.5
    11
    ±5
    or
    ±2
    ×2.5
    0.4 Dyn11 190 670 710 760 2.4 4.0 35 900x900x800 300
    50 270 940 1000 1070 2.4 955x900x900 350
    80 370 1290 1380 1480 1.8 36 985x950x960 400
    100 400 1480 1570 1690 1.8 1035x1250x980 450
    125 470 1740 1850 1980 1.6 37 1060x1280x1000 500
    160 540 2000 2130 2280 1.6 1120x1320x1050 680
    200 620 2370 2530 2710 1.4 38 1130x1330x1015 770
    250 720 2590 2760 2960 1.4 1170x1330x1165 900
    315 880 3270 3470 3730 1.2 39 1185x1360x1225 1010
    400 980 3750 3990 4280 1.2 1210x1380x1300 1205
    500 1160 4590 4880 5230 1.2 40 1245x1400x1380 1400
    630 1340 5530 5880 6290 1 6.0 41 1295x1410x1355 1515
    630 1300 5610 5960 6400 1 1295x1410x1355 1515
    800 1520 6550 6960 7460 1 42 1375x1450x1480 1830
    1000 1770 7650 8130 8760 1 1430x1480x1525 2170
    1250 2090 9100 9690 10370 1 43 1480x1500x1570 2525
    1600 2450 11050 11730 12580 1 44 1500x1520x1710 2930
    2000 3050 13600 14450 15560 0.8 45 1570x1550x1735 3430
    2500 3600 16150 17170 18450 0.8 46 1625x1600x1825 4030
    1600 2450 12280 12960 13900 1 8.0 44 1500x1520x1710 2930
    2000 3050 15020 15960 17110 0.8 45 1570x1550x1735 3430
    2500 3600 17760 18890 20290 0.8 46 1625x1610x1825 4080
    Note: Due to the continuous updating of products, the dimensions and weight of the products in the table may change. Please refer to the dimensions provided when ordering.

    SCB11-RL-(30-2500)/11Three-dimensional triangle core dry-type power transformer

    Rated capacity (KVA) Voltage combination Connection Group Label No load Power consumption (W) Load loss group A (W) No load Current(%) Short circuit impedance (%) Sound Power class dB(A) Dimensions (mm (length, width and height) Installation 4φ18 Total weight (kg)
    high pressure (KV) Demarcation range Low pressure 100°C 100°C 100°C
    B(100°C) F(120°C) H(145°C)
    30 6
    6.3
    6.6
    10
    10.5
    11
    ±5
    or
    ±2
    ×2.5
    0.4 Dyn11 670 710 760 2.4 4.0 35 900x900x800 300
    50 940 1000 1070 2.4 955x900x900 350
    80 1290 1380 1480 1.8 36 985x950x960 400
    100 1480 1570 1690 1.8 1035x1250x980 450
    125 1740 1850 1980 1.6 37 1060x1280x1000 500
    160 2000 2130 2280 1.6 1120x1320x1050 680
    200 2370 2530 2710 1.4 38 1130x1330x1015 770
    250 2590 2760 2960 1.4 1170x1330x1165 900
    315 3270 3470 3730 1.2 39 1185x1360x1225 1010
    400 3750 3990 4280 1.2 1210x1380x1300 1205
    500 4590 4880 5230 1.2 40 1245x1400x1380 1400
    630 5530 5880 6290 1 6.0 41 1295x1410x1355 1515
    630 5610 5960 6400 1 1295x1410x1355 1515
    800 6550 6960 7460 1 42 1375x1450x1480 1830
    1000 7650 8130 8760 1 1430x1480x1525 2170
    1250 9100 9690 10370 1 43 1480x1500x1570 2525
    1600 11050 11730 12580 1 44 1500x1520x1710 2930
    2000 13600 14450 15560 0.8 45 1570x1550x1735 3430
    2500 16150 17170 18450 0.8 46 1625x1600x1825 4030
    1600 12280 12960 13900 1 8.0 44 1500x1520x1710 2930
    2000 15020 15960 17110 0.8 45 1570x1550x1735 3430
    2500 17760 18890 20290 0.8 46 1625x1610x1825 4080
    Note: Due to the continuous updating of products, the dimensions and weight of the products in the table may change. Please refer to the dimensions provided when ordering.

    SCB13-RL-(30-2500)/13Three-dimensional triangle core dry-type power transformer

    Rated capacity (KVA) Voltage combination Connection Group Label No load Power consumption (W) Load loss group A (W) No load Current(%) Short circuit impedance (%) Sound Power class dB(A) Dimensions (mm (length, width and height) Installation 4φ18 Total weight (kg)
    high pressure (KV) Demarcation range Low pressure 100°C 100°C 100°C
    B(100°C) F(120°C) H(145°C)
    30 6
    6.3
    6.6
    10
    10.5
    11
    ±5
    or
    ±2
    ×2.5
    0.4 Dyn11 670 710 760 2.4 4.0 35 900x900x800 300
    50 940 1000 1070 2.4 955x900x900 350
    80 1290 1380 1480 1.8 36 985x950x960 400
    100 1480 1570 1690 1.8 1035x1250x980 450
    125 1740 1850 1980 1.6 37 1060x1280x1000 500
    160 2000 2130 2280 1.6 1120x1320x1050 680
    200 2370 2530 2710 1.4 38 1130x1330x1015 770
    250 2590 2760 2960 1.4 1170x1330x1165 900
    315 3270 3470 3730 1.2 39 1185x1360x1225 1010
    400 3750 3990 4280 1.2 1210x1380x1300 1205
    500 4590 4880 5230 1.2 40 1245x1400x1380 1400
    630 5530 5880 6290 1 6.0 41 1295x1410x1355 1515
    630 5610 5960 6400 1 1295x1410x1355 1515
    800 6550 6960 7460 1 42 1375x1450x1480 1830
    1000 7650 8130 8760 1 1430x1480x1525 2170
    1250 9100 9690 10370 1 43 1480x1500x1570 2525
    1600 11050 11730 12580 1 44 1500x1520x1710 2930
    2000 13600 14450 15560 0.8 45 1570x1550x1735 3430
    2500 16150 17170 18450 0.8 46 1625x1600x1825 4030
    1600 12280 12960 13900 1 8.0 44 1500x1520x1710 2930
    2000 15020 15960 17110 0.8 45 1570x1550x1735 3430
    2500 17760 18890 20290 0.8 46 1625x1610x1825 4080
    Note: Due to the continuous updating of products, the dimensions and weight of the products in the table may change. Please refer to the dimensions provided when ordering.

    Frequently Asked Questions (FAQ)

    What is a three-dimensional triangle core dry-type power transformer?
    It is an advanced dry-type power transformer featuring a wound core design where the three core limbs are arranged in a symmetrical, three-dimensional triangular structure. This configuration balances the three-phase magnetic circuit, reduces no-load losses, and significantly lowers noise levels.
    What are the main differences between SCB11 and SCB13 series transformers?
    The primary difference lies in efficiency and energy savings. The SCB13 series has a more optimized core structure and material design, which results in lower no-load power consumption and reduced operating losses compared to the SCB11 series.
    How does the insulation temperature class affect load loss?
    Load loss values vary depending on the operating temperature limit of the insulation class used: Class B (100°C), Class F (120°C), and Class H (145°C). Higher insulation classes allow the transformer to run safely at higher thermal limits, altering the load loss parameters accordingly.
    Why do dimensions and weights in the tables vary slightly?
    Due to continuous technology upgrades, structural optimizations, and potential customization requirements (such as enclosure types or terminal configurations), physical dimensions and overall weights are subject to change. Always verify the manufacturer's outline drawing before finalizing installation spaces.
    What connection group label is standard for these transformers?
    The standard connection group label for these three-dimensional triangle core transformers is Dyn11, which provides excellent performance in handling unbalanced loads and suppressing third harmonics.

    Leave Your Message

    AI Helps Write