Leave Your Message

China Suppliers Factory Air-12/T630-25 Environmentally-Friendly Gas-Insulated Metal-Enclosed Switchgear

,

Overview

,

The Air-12 Environmentally-Friendly Gas-Insulated Metal-Enclosed Switchgear is a cutting-edge solution that incorporates a vacuum arc-extinguishing chamber, utilizing eco-friendly gas as the primary insulating medium alongside minimal solid insulating supports. This innovative design ensures that the main circuit remains uncapsulated, operating under zero gauge pressure or slightly positive pressure (with gas pressure in the tank ≤ 0.02 MPa). The insulation efficiency between phases and to ground meets air insulation standards for distribution switchgear, functioning seamlessly under these pressure conditions.
As one of the most sought-after three-phase AC intelligent eco-friendly gas-insulated cabinets, this equipment finds extensive applications in various complete switchgear systems. With the ongoing concentration of population and industrial development in China, the demand for environmentally friendly gas-insulated switchgear continues to rise, presenting significant market potential for suppliers and manufacturers alike.
This product is designed not only for high performance but also for intelligence. It integrates features such as data collection and control, data processing, online monitoring of the switchgear, and sophisticated analysis. These capabilities promote intelligent online monitoring and management of the distribution network, ensuring operations that are safe, reliable, and efficient. This advanced system meets the pressing needs for grid optimization, electrical safety, energy management, and conservation. Its versatile application spans intelligent distribution sectors, including transportation, factories, hospitals, educational institutions, buildings, residential communities, and commercial office spaces. Trust in our factory to deliver the most efficient and sustainable solutions for your power distribution needs.

,

    Model and Definitions
    Model and Definitions
    Normal Use Environmental Conditions
    ☀️
    Maximum Temperature: +40℃
    ❄️
    Minimum Temperature: -25℃
    🕒
    24-Hour Average Temperature: ≤35℃
    💧
    Maximum Average Relative Humidity: 24-Hour Average ≤95%, Monthly Average: ≤90%
    ⛰️
    Altitude: ≤1500 meters (for standard type, under standard gas pressure); special instructions required for >1500 meters
    ⚠️
    For special operating conditions beyond normal use environment, prior consultation with our company is recommended.
    Major Technical Parameters
    Units Items C Module F Module V Module
    Load Switch Composite Apparatu Vacuum Breaker lsolation/ Earthing Switch
    1 Nominal Voltage kV 12
    2 1min Power Frequency Withstand Voltage kV 42/48
    3 Lighting lmpulse Withstand Voltage kv 75/85
    4 Rated Currency A 630 630 630
    5 Breaking Capacity
    Closed Loop Breaking Current (A) 630
    Cable Charging Breaking Current(A) 135
    5% Active Load Breaking Current(A) 31.5
    Ground Fault Breaking Current(A) 200
    Short-Circuit Breaking Current (kA) 31.5∗ 25
    6 Rated Transfer Current A 1500
    7 Maximum Current Near Circuit Breaker(A) 125
    8 Short-Circuit Closing Current (kA) 63 80∗ 25
    9 Short-Time Withstand Current(KA) 25 25 25
    10 Short-Circuit Duration (s) 4 4 4
    11 Machinery Service Life Time 5000 5000 10000 3000
    12 Gas Pressure(MPa) 0.025(20°C)
    13 Annual Leakage Rate ≤0.05%
    14 Arc Extinguishing Method Vacuum Extinction
    15 Level of Protection IP67/3X(Gas Tank/Sell)
    External Dimensions
    External Dimensions
    Dimension 1-way 2-way 3-way 4-way 5-way
    W (mm) 371 696 1021 1346 1671
    H (mm) 1336
    D (mm) 850 (total 935)
    Outdoor Open and Close Solution
    Outdoor Open and Close Solution
    Frequently Asked Questions
    What are the normal operating temperature limits for this equipment?
    The equipment is designed to operate within a maximum temperature of +40℃ and a minimum temperature of -25℃, with a 24-hour average temperature not exceeding 35℃.
    Can the equipment be installed at altitudes higher than 1500 meters?
    The standard type is rated for altitudes ≤1500 meters under standard gas pressure. For installation environments above 1500 meters, special instructions and prior consultation with our company are required.
    What is the level of protection for the gas tank and shell?
    The protection level is rated at IP67 for the gas tank and IP3X for the external shell, ensuring robust environmental sealing.
    What is the mechanical service life of the different modules?
    The machinery service life is 5,000 times for the C Module (Load Switch) and F Module (Composite Apparatus), 10,000 times for the V Module (Vacuum Breaker), and 3,000 times for the Isolation/Earthing Switch.
    What is the annual gas leakage rate and the arc extinguishing method used?
    The equipment features a low annual gas leakage rate of ≤0.05% and utilizes a highly efficient Vacuum Extinction method for arc extinguishing.
    How do the width dimensions change from 1-way to 5-way configurations?
    The width (W) scales as follows: 1-way is 371mm, 2-way is 696mm, 3-way is 1021mm, 4-way is 1346mm, and 5-way is 1671mm. The height (H: 1336mm) and depth (D: 850mm / total 935mm) remain constant across all configurations.