Introducing our triangle three-dimensional wound core dry-type power transformer, a cutting-edge power transformation solution designed for optimal performance and reliability. This transformer utilizes natural air convection for cooling and, if needed, can integrate fan cooling, ensuring efficient operation without the immersion in insulating liquids. Known for its exceptional heat resistance and fire safety, this transformer is ideal for penetrating deep into load centers, making it perfect for power transmission and transformation across high-rise buildings, commercial centers, industrial and mining sectors, oil platforms, subways, and tunnels. As a leading China manufacturer, we pride ourselves on delivering top-quality products. Trust our factory for your power transformer needs and enhance your energy solutions.

,

    Model meaning
    product-description1
    Rated capacity
    (KVA)
    Voltage combination Connection
    Group
    Label
    No load
    Power
    consumption
    (W)
    Load loss group A (W) No
    load
    Current(%)
    Short
    circuit
    impedance
    (%)
    Sound
    Power
    class
    dB(A)
    Dimensions
    (mm (length,
    width
    and height)
    Installation 4φ18
    Total
    weight
    (kg)
    high
    pressure
    (KV)
    Demarcation
    range
    Low
    pressure
    100°C 100°C 100°C
    B(100°C) F(120°C) H(145°C)
    30 6
    6.3
    6.6
    10
    10.5
    11
    ±5
    or
    ±2
    ×2.5
    0.4 Dyn11 190 670 710 760 2.4 4.0 35 900x900x800 300
    50 270 940 1000 1070 2.4 955x900x900 350
    80 370 1290 1380 1480 1.8 36 985x950x960 400
    100 400 1480 1570 1690 1.8 1035x1250x980 450
    125 470 1740 1850 1980 1.6 37 1060x1280x1000 500
    160 540 2000 2130 2280 1.6 1120x1320x1050 680
    200 620 2370 2530 2710 1.4 38 1130x1330x1015 770
    250 720 2590 2760 2960 1.4 1170x1330x1165 900
    315 880 3270 3470 3730 1.2 39 1185x1360x1225 1010
    400 980 3750 3990 4280 1.2 1210x1380x1300 1205
    500 1160 4590 4880 5230 1.2 40 1245x1400x1380 1400
    630 1340 5530 5880 6290 1 6.0 41 1295x1410x1355 1515
    630 1300 5610 5960 6400 1 1295x1410x1355 1515
    800 1520 6550 6960 7460 1 42 1375x1450x1480 1830
    1000 1770 7650 8130 8760 1 1430x1480x1525 2170
    1250 2090 9100 9690 10370 1 43 1480x1500x1570 2525
    1600 2450 11050 11730 12580 1 44 1500x1520x1710 2930
    2000 3050 13600 14450 15560 0.8 45 1570x1550x1735 3430
    2500 3600 16150 17170 18450 0.8 46 1625x1600x1825 4030
    1600 2450 12280 12960 13900 1 8.0 44 1500x1520x1710 2930
    2000 3050 15020 15960 17110 0.8 45 1570x1550x1735 3430
    2500 3600 17760 18890 20290 0.8 46 1625x1610x1825 4080
    Note: Due to the continuous updating of products, the dimensions and weight of the products in the table may change. Please refer to the dimensions provided when ordering.
    SCB11-RL-(30-2500)/11Three-dimensional triangle core dry-type power transformer
    Rated capacity
    (KVA)
    Voltage combination Connection
    Group
    Label
    No load
    Power
    consumption
    (W)
    Load loss group A (W) No
    load
    Current(%)
    Short
    circuit
    impedance
    (%)
    Sound
    Power
    class
    dB(A)
    Dimensions
    (mm (length,
    width
    and height)
    Installation 4φ18
    Total
    weight
    (kg)
    high
    pressure
    (KV)
    Demarcation
    range
    Low
    pressure
    100°C 100°C 100°C
    B(100°C) F(120°C) H(145°C)
    30 6
    6.3
    6.6
    10
    10.5
    11
    ±5
    or
    ±2
    ×2.5
    0.4 Dyn11 670 710 760 2.4 4.0 35 900x900x800 300
    50 940 1000 1070 2.4 955x900x900 350
    80 1290 1380 1480 1.8 36 985x950x960 400
    100 1480 1570 1690 1.8 1035x1250x980 450
    125 1740 1850 1980 1.6 37 1060x1280x1000 500
    160 2000 2130 2280 1.6 1120x1320x1050 680
    200 2370 2530 2710 1.4 38 1130x1330x1015 770
    250 2590 2760 2960 1.4 1170x1330x1165 900
    315 3270 3470 3730 1.2 39 1185x1360x1225 1010
    400 3750 3990 4280 1.2 1210x1380x1300 1205
    500 4590 4880 5230 1.2 40 1245x1400x1380 1400
    630 5530 5880 6290 1 6.0 41 1295x1410x1355 1515
    630 5610 5960 6400 1 1295x1410x1355 1515
    800 6550 6960 7460 1 42 1375x1450x1480 1830
    1000 7650 8130 8760 1 1430x1480x1525 2170
    1250 9100 9690 10370 1 43 1480x1500x1570 2525
    1600 11050 11730 12580 1 44 1500x1520x1710 2930
    2000 13600 14450 15560 0.8 45 1570x1550x1735 3430
    2500 16150 17170 18450 0.8 46 1625x1600x1825 4030
    1600 12280 12960 13900 1 8.0 44 1500x1520x1710 2930
    2000 15020 15960 17110 0.8 45 1570x1550x1735 3430
    2500 17760 18890 20290 0.8 46 1625x1610x1825 4080
    Note: Due to the continuous updating of products, the dimensions and weight of the products in the table may change. Please refer to the dimensions provided when ordering.
    SCB13-RL-(30-2500)/13Three-dimensional triangle core dry-type power transformer
    Rated capacity
    (KVA)
    Voltage combination Connection
    Group
    Label
    No load
    Power
    consumption
    (W)
    Load loss group A (W) No
    load
    Current(%)
    Short
    circuit
    impedance
    (%)
    Sound
    Power
    class
    dB(A)
    Dimensions
    (mm (length,
    width
    and height)
    Installation 4φ18
    Total
    weight
    (kg)
    high
    pressure
    (KV)
    Demarcation
    range
    Low
    pressure
    100°C 100°C 100°C
    B(100°C) F(120°C) H(145°C)
    30 6
    6.3
    6.6
    10
    10.5
    11
    ±5
    or
    ±2
    ×2.5
    0.4 Dyn11 670 710 760 2.4 4.0 35 900x900x800 300
    50 940 1000 1070 2.4 955x900x900 350
    80 1290 1380 1480 1.8 36 985x950x960 400
    100 1480 1570 1690 1.8 1035x1250x980 450
    125 1740 1850 1980 1.6 37 1060x1280x1000 500
    160 2000 2130 2280 1.6 1120x1320x1050 680
    200 2370 2530 2710 1.4 38 1130x1330x1015 770
    250 2590 2760 2960 1.4 1170x1330x1165 900
    315 3270 3470 3730 1.2 39 1185x1360x1225 1010
    400 3750 3990 4280 1.2 1210x1380x1300 1205
    500 4590 4880 5230 1.2 40 1245x1400x1380 1400
    630 5530 5880 6290 1 6.0 41 1295x1410x1355 1515
    630 5610 5960 6400 1 1295x1410x1355 1515
    800 6550 6960 7460 1 42 1375x1450x1480 1830
    1000 7650 8130 8760 1 1430x1480x1525 2170
    1250 9100 9690 10370 1 43 1480x1500x1570 2525
    1600 11050 11730 12580 1 44 1500x1520x1710 2930
    2000 13600 14450 15560 0.8 45 1570x1550x1735 3430
    2500 16150 17170 18450 0.8 46 1625x1600x1825 4030
    1600 12280 12960 13900 1 8.0 44 1500x1520x1710 2930
    2000 15020 15960 17110 0.8 45 1570x1550x1735 3430
    2500 17760 18890 20290 0.8 46 1625x1610x1825 4080
    Note: Due to the continuous updating of products, the dimensions and weight of the products in the table may change. Please refer to the dimensions provided when ordering.
    Frequently Asked Questions (FAQ)
    What do the model designations SCB11-RL and SCB13-RL stand for?
    "SCB" designates a resin-cast dry-type transformer. The numbers "11" and "13" represent the performance level generation codes (with 13 being more energy-efficient), and "RL" refers to the three-dimensional triangular core structure.
    What are the primary advantages of a three-dimensional triangle core design?
    The three-dimensional triangular core structure provides a balanced three-phase magnetic circuit, which significantly reduces no-load loss, no-load current, and operational noise levels compared to traditional planar cores.
    What voltage combinations are supported by these dry-type transformers?
    They support high-voltage ratings of 6kV, 6.3kV, 6.6kV, 10kV, 10.5kV, or 11kV (with demarcation ranges of ±5% or ±2×2.5%) and a standard low-voltage output of 0.4kV.
    How does temperature class affect the load loss group values?
    Load losses are calculated based on the reference insulation system temperatures. The tables outline load loss limits for Class B (100°C), Class F (120°C), and Class H (145°C) to match diverse operational environments.
    Why might the actual dimensions and weights differ from the product tables?
    As products undergo continuous technological optimization and structural updates, physical dimensions and weight figures are subject to minor adjustments. It is recommended to confirm final drawings when placing an order.
    What is the standard connection group label for these models?
    The standard connection group configuration is Dyn11, which offers superior performance in mitigating harmonic currents and handling unbalanced loads.

    Leave Your Message