Leave Your Message

China S11-M-ZT On-Load Capacity-Changing Transformer - Energy-Saving Solution from Leading Suppliers and Factory

,

Overview
The S11-M-ZT on-load capacity-adjusting transformer is an innovative product developed independently by our factory, aimed at enhancing energy efficiency in power distribution systems. As a leading transformer solution from China, this new technology combines two rated capacities—large and small—with the ability to automatically adjust capacity based on load demands. This capability addresses the significant seasonal load variations in 10kV distribution networks, effectively minimizing transformer losses.

,

By utilizing the S11-M-ZT transformer, our suppliers can reduce both equipment purchase and installation costs compared to deploying two traditional S11 type transformers. This product requires less installation space and considerably lowers construction, operation, and maintenance workloads. Notably, the S11-M-ZT transformer also boasts a remarkable reduction of 50% in no-load losses compared to standard S11 transformers.

,

This versatile transformer is not only ideal for rural power grids experiencing significant seasonal load fluctuations, but it is also well-suited for urban commercial areas, development zones, industrial regions, radio stations, and oil fields, where day and night load variations are prevalent.

,

    Reliable structure

    Based on the traditional structure and mature technology, our company has made many improvements, such as:
    Spiral coil with longitudinal oil channel for better internal heat dissipation;
    The effective support of the coil end face has been improved, and the ability to resist short-circuit current is stronger;
    The new hoisting structure and body positioning structure are adopted to ensure more reliability in long-distance transportation and operation;
    We also have many unique and reliable structures to serve you;
    Choosing a transformer with a higher performance level will have a higher level of technical content.

    High-quality materials

    Use oxygen-free copper wire with lower resistivity, and after a series of additional surface treatment, it is smoother and has no burrs or sharp corners, which makes the load loss of the transformer lower and the electrical performance more reliable:
    Select high-quality silicon steel sheets. As the performance level improves, silicon steel sheets with lower unit loss are used to reduce the no-load loss of the transformer.
    Made of high-quality laminated wood insulation, it will never crack and will not move even under the action of short- circuit current.
    Use deep-filtered transformer oil with lower water, gas and impurity levels, making the transformer work more reliable.
    Use high-quality rubber sealing materials to effectively prevent aging and prevent leakage.
    All raw materials have undergone quality inspection to effectively prevent aging and prevent leakage.
    All raw materials have been quality inspected, and all raw material factories have been inspected according to national standards. ISO9000strict scrutiny.

    Good technical and economic performance

    This product can significantly reduce the transformer no-load loss by 50-60%
    Reduce reactive power loss of power grid by 20-30%
    If this technology is fully applied to rural power grids, it can save 10 billion kWh of electricity each year;
    Save 3 million tons of standard coal per year, equivalent to dry emission reduction CO 2500 Ten thousand tons.
    The project has been highly valued by the State Grid Corporation of China, included in the National 11th Five-Year Electricity Saving Plan undertaken by the National Electric Power Research Institute, and compiled into the power construction specifications in the new rural construction.

    Fully sealed

    SelectS11(M) RIn M The oil tank adopts a fully sealed structure. Compared with ordinary oil-immersed transformers, the fully sealed distribution transformer eliminates the oil storage cabinet, and the corrugated fins of the oil tank replace the oil pipes. In order to cool the heat dissipation components, the corrugated oil tank is made of high-quality cold-rolled thin plates on a special production line. The corrugated fins can adjust the expansion and contraction of the transformer oil, thereby isolating the transformer from the atmosphere, preventing and slowing down oil deterioration and insulation moisture, enhancing operational reliability, and ensuring maintenance-free normal operation.
    The surface of the corrugated oil tank is degreased, derusted, phosphated and then painted with three-proof paint. It is suitable for use in metallurgy, petrochemical, mining and other environments.

    Transformer pro duct standards

    GB1094 .1-1996  GB1094 .2-1996  GB1094 .3-2003  GB1094 . 1   GB1094 .5-2003
    JB/T10088-2004  GB/T10237-1988 GB-T6451-2008   GB-T7595-1987
    JB/T 3837-1998  JB/T 10778-2007

    Normal operating conditions of transformer

    Altitude not exceeding 1000m;
    Ambient temperature: maximum temperature +40℃; average temperature of the hottest month +30℃; maximum annual average temperature +20℃; minimum outdoor temperature -25℃.

    Special conditions for use of transformers

    Altitude not exceeding 1000m;
    Ambient temperature: Maximum temperature +40℃; Minimum temperature -25℃.

    Model meaning

    Model meaning

    S11-M-ZT Technical parameters of on-load capacity-adjusting transformer

    Rated capacity
    (KVA)
    Voltage combination (kV) Connection method Loss (kW) No-load current
    (%)
    Impedance voltage
    (%)
    weight(Kg) Dimensions(mm)
    (LengthL * Width B * Height L)
    (LengthL × Width B×Height H)
    gauge
    (Vertical/
    Horizontal)
    high pressure Low pressure No load load (75°C) Heavy Oil weight Total weight
    630/200 10
    10.5
    11
    0.4 Yyn0
    Dyn11
    810(340) 8030(3060) 1.3(1.8) 4.5 1455 600 2600 2040x1150x1470 820x820
    500/160 680(280) 6520(2600) 1.4(1.9) 4 1150 495 2130 1925x1090x1455 820x820
    400/125 570(240) 5480(213) 1.5(2) 970 415 1860 1870x1060x1450 820x820
    315/100 480(200) 4540(1770) 1.6(2.1) 860 385 1540 1780x1005x1315 820x820
    250/80 400(180) 3780(1480) 1.7(2.2) 680 340 1390 1705x980x1270 820x750
    200/63 340(150) 3215(1230) 1.8(2.4) 585 310 1235 1685x960x1240 820x750
    160/50 280(130) 2590(1030) 1.9(2.5) 505 290 1090 1650x940x1200 820x750
    100/30 200(100) 1580(630) 2.1(2.8) 360 240 870 1540x885x1150 820x750

    Overall dimensions and installation dimensions

    Overall dimensions and installation dimensions

    Frequently Asked Questions (FAQ)

    What are the primary energy-saving advantages of this capacity-adjusting transformer?
    This product significantly reduces transformer no-load loss by 50-60% and lowers grid reactive power loss by 20-30%, resulting in substantial long-term electricity and emission savings.
    How does the fully sealed oil tank structure improve performance?
    The corrugated fins adjust to oil expansion and contraction, isolating the transformer oil from atmospheric exposure. This prevents oil deterioration, inhibits insulation moisture, and enables maintenance-free operation.
    What materials ensure the mechanical and electrical reliability of the transformer?
    The unit utilizes smooth oxygen-free copper wires with low resistivity, high-grade silicon steel sheets, crack-resistant laminated wood insulation, and deep-filtered transformer oil with low impurity levels.
    What are the standard ambient operating conditions?
    The transformer is designed for altitudes not exceeding 1000m, with ambient temperatures ranging from a maximum of +40℃ to an outdoor minimum of -25℃.
    Which manufacturing and industry standards does the transformer comply with?
    It adheres to standard national and industry specifications including the GB1094 series, JB/T10088-2004, GB/T10237-1988, GB-T6451-2008, GB-T7595-1987, JB/T 3837-1998, and JB/T 10778-2007.

    Leave Your Message