Leave Your Message

China S11-M-ZT On-Load Capacity-Changing Transformer - Energy-Saving Solution by Leading Suppliers and Factory

,

Overview
The S11-M-ZT on-load capacity-adjusting transformer is an innovative energy-saving distribution transformer, independently developed by our company in China. This advanced technology product features dual rated capacities—large and small—allowing for two fixed capacity operation modes that can automatically adjust according to load demands. This capability addresses the significant seasonal load variations often seen in 10kV distribution networks, which lead to excessive transformer losses. By eliminating the need for a disconnected transformer, the S11-M-ZT offers a cost-effective solution compared to utilizing two separate S11 transformers, thereby reducing equipment purchase and installation costs, as well as the physical space required. Additionally, this transformer greatly minimizes construction workload and operational maintenance efforts. Notably, the no-load loss of the S11-M-ZT type is reduced by 50% compared to conventional S11 transformers. It is ideal for rural power grids with significant seasonal load changes, as well as urban commercial areas, development zones, industrial sites, radio stations, and oil fields, where daily load fluctuations are pronounced. Choose our S11-M-ZT transformer from a leading China supplier to enhance your energy efficiency and reliability.

,

    Reliable structure

    ◆ Based on the traditional structure and mature technology, our company has made many improvements, such as:
    • Spiral coil with longitudinal oil channel for better internal heat dissipation;
    • The effective support of the coil end face has been improved, and the ability to resist short-circuit current is stronger;
    • The new hoisting structure and body positioning structure are adopted to ensure more reliability in long-distance transportation and operation;
    • We also have many unique and reliable structures to serve you;
    • Choosing a transformer with a higher performance level will have a higher level of technical content.

    High-quality materials

    • Use oxygen-free copper wire with lower resistivity, and after a series of additional surface treatment, it is smoother and has no burrs or sharp corners, which makes the load loss of the transformer lower and the electrical performance more reliable.
    • Select high-quality silicon steel sheets. As the performance level improves, silicon steel sheets with lower unit loss are used to reduce the no-load loss of the transformer.
    • Made of high-quality laminated wood insulation, it will never crack and will not move even under the action of short- circuit current.
    • Use deep-filtered transformer oil with lower water, gas and impurity levels, making the transformer work more reliable.
    • Use high-quality rubber sealing materials to effatively prevent aging and prevent leakage.
    • All raw materials have undergone quality inspection to effatively prevent aging and prevent leakage.
    • All raw materials have been quality inspected, and all raw material factories have been inspected according to national standards. ISO9000 strict scrutiny.

    Good technical and economic performance

    • This product can significantly reduce the transformer no-load loss by 50-60%
    • Reduce reactive power loss of power grid by 20-30%
    • If this technology is fully applied to rural power grids, it can save 10 billion kWh of electricity each year;
    • Save 3 million tons of standard coal per year, equivalent to dry emission reduction CO 2500 Ten thousand tons.
    • The project has been highly valued by the State Grid Corporation of China, included in the National 11th Five-Year Electricity Saving Plan undertaken by the National Electric Power Research Institute, and compiled into the power construction specifications in the new rural construction.

    Fully sealed

    ◇ Select S11(M) R In M The oil tank adopts a fully sealed structure. Compared with ordinary oil-immersed transformers, the fully sealed distribution transformer eliminates the oil storage cabinet, and the corrugated fins of the oil tank replace the oil pipes. In order to cool the heat dissipation components, the corrugated oil tank is made of high-quality cold-rolled thin plates on a special production line. The corrugated fins can adjust the expansion and contraction of the transformer oil, thereby isolating the transformer from the atmosphere, preventing and slowing down oil deterioration and insulation moisture, enhancing operational reliability, and ensuring maintenance-free normal operation.

    ◇ The surface of the corrugated oil tank is degreased, derusted, phosphated and then painted with three-proof paint. It is suitable for use in metallurgy, petrochemical, mining and other environments.

    Transformer product standards

    GB1094.1-1996 GB1094.2-1996 GB1094.3-2003 GB1094.1 GB1094.5-2003 JB/T10088-2004 GB/T10237-1988 GB-T6451-2008 GB-T7595-1987 JB/T 3837-1998 JB/T 10778-2007
    Normal operating conditions of transformer
    • Altitude not exceeding 1000m;
    • Ambient temperature: maximum temperature +40℃; average temperature of the hottest month +30℃; maximum annual average temperature +20℃; minimum outdoor temperature -25℃.
    Special conditions for use of transformers
    • Altitude not exceeding 1000m;
    • Ambient temperature: Maximum temperature +40℃; Minimum temperature -25℃.

    Model meaning

    product-description1

    S11-M-ZT Technical parameters of on-load capacity-adjusting transformer

    Rated capacity (KVA) Voltage combination (kV) Connection method Loss (kW) No-load current (%) Impedance voltage (%) Weight (Kg) Dimensions (mm)
    (L * W * H)
    Gauge
    (Vert/Horiz)
    High pressure Low pressure No load Load (75°C) Heavy Oil weight Total weight
    630/200 10
    10.5
    11
    0.4 Yyn0
    Dyn11
    810(340) 8030(3060) 1.3(1.8) 4.5 1455 600 2600 2040x1150x1470 820x820
    500/160 680(280) 6520(2600) 1.4(1.9) 4 1150 495 2130 1925x1090x1455 820x820
    400/125 570(240) 5480(213) 1.5(2) 970 415 1860 1870x1060x1450 820x820
    315/100 480(200) 4540(1770) 1.6(2.1) 860 385 1540 1780x1005x1315 820x820
    250/80 400(180) 3780(1480) 1.7(2.2) 680 340 1390 1705x980x1270 820x750
    200/63 340(150) 3215(1230) 1.8(2.4) 585 310 1235 1685x960x1240 820x750
    160/50 280(130) 2590(1030) 1.9(2.5) 505 290 1090 1650x940x1200 820x750
    100/30 200(100) 1580(630) 2.1(2.8) 360 240 870 1540x885x1150 820x750

    Overall dimensions and installation dimensions

    product-description2

    Frequently Asked Questions (FAQ)

    Q What structural improvements make this transformer more reliable?
    Our transformers feature spiral coils with longitudinal oil channels for enhanced internal heat dissipation, improved coil end face support to resist short-circuit currents, and a specialized hoisting and positioning structure to ensure stability during transport.
    Q How does the fully sealed design benefit the transformer's operation?
    The fully sealed structure eliminates the traditional oil storage cabinet, replacing oil pipes with corrugated fins that adjust to oil expansion and contraction. This isolates the oil from the atmosphere, preventing moisture ingress and oil deterioration, which ensures maintenance-free operation.
    Q What are the environmental and energy-saving benefits of this technology?
    This technology reduces no-load loss by 50-60% and reactive power loss by 20-30%. When implemented in rural power grids, it can save up to 10 billion kWh of electricity and reduce standard coal consumption by 3 million tons annually.
    Q What materials are used to ensure the electrical performance of the transformer?
    We use high-purity oxygen-free copper wire with low resistivity, high-grade silicon steel sheets to minimize no-load losses, laminated wood insulation to resist cracking under short-circuit stress, and deep-filtered transformer oil with minimal impurities.
    Q What are the standard operating conditions for these transformers?
    The standard operating conditions require an altitude not exceeding 1000 meters. The ambient temperature range should be between a maximum of +40℃ and a minimum of -25℃, with a maximum annual average temperature of +20℃.
    Q Which national and industry standards do these transformers comply with?
    Our products fully comply with several key standards, including GB1094.1, GB1094.2, GB1094.3, GB1094.5, JB/T10088, GB/T10237, GB-T6451, GB-T7595, JB/T 3837, and JB/T 10778.

    Leave Your Message