Leave Your Message

China JXF Low Voltage Distribution Box Series - Reliable Power Control Solutions from Trusted Suppliers and Factory

,

Product Overview

,

The JXF Control Box is designed for use in 50Hz environments with voltages up to 500V, featuring a load current capacity not exceeding 250A. It is suitable for three-phase three-wire, three-phase four-wire, and three-phase five-wire systems, effectively managing power distribution while providing essential leakage protection. With its innovative design, compact size, and aesthetically pleasing appearance, this control box ensures safe and reliable operation. It is widely utilized across various sectors, including metallurgy, petrochemicals, healthcare, aviation, residential developments, shopping malls, educational institutions, and urban redevelopment projects. As a leading product from China, our JXF Control Box exemplifies quality and efficiency, making it a preferred choice among suppliers and factories looking for dependable solutions in electrical control systems.

,

    Model and Definitions

    Model and Definitions

    Use Environment and Conditions

    • Altitude not exceeding 2000m;
    • The ambient air temperature shall not exceed +40℃ and shall not be lower than -25℃;
    • At +20℃, the monthly average relative humidity of the air is no more than 40%;
    • A place without severe vibration and impact;
    • There are no explosive hazardous areas, and there are no gases or conductive dust in the medium that can corrode metals or damage insulation.

    Structural characteristics

    • Multiple series, multiple structures, welded, split, assembled; outdoor, indoor;
    • A variety of double-door structures, safe and reliable to use;
    • Multi-level protection IP20, IP40, IP43, IP54, IP65; Can meet the needs of different places;
    Structural characteristics

    Dimensions (welded)

    Specification high H(mm) Width W (mm) Deep D(mm) Thickness of iron sheet Structural Feature
    2520/14 250 200 140 1.2
    1.5
    JXF comes in two types: surface mounted and concealed. JFF is divided into two types: metal doors and perspective window doors. The door panels are affixed with sealing rubber strips to prevent rainwater from seeping in. The box is equipped with upper and lower inlet and outlet holes, as well as an installation base. The inlet and outlet holes have been equipped with sealing plates at the factory, and the door opening angle is greater than 90°. JXF and JFF1 each have 25 specifications, while JFF2 has 18 specifications.
    3025/14 300 250 140
    3025/18 300 250 180
    3030/14 300 300 140
    3030/18 300 300 180
    4030/14 400 300 140
    4030/20 400 300 200
    5040/14 500 400 140
    5040/20 500 400 200
    5040/23 500 400 230
    6040/14 600 400 140
    6040/20 600 400 200
    6040/23 600 400 230
    6050/14 600 500 140
    6050/20 600 500 200
    6050/23 600 500 230
    7050/16 700 500 160
    7050/20 700 500 200
    7050/23 700 500 230
    8060/20 800 600 200
    8060/23 800 600 230
    8060/25 800 600 250
    10080/20 1000 800 200
    10080/25 1000 800 250
    10080/30 1000 800 300
    Note: The cabinet dimensions can be determined based on the drawings provided by the customer.

    order cargo Information

    • Please specify when ordering:
    • Model;
    • Installation method;
    • Structural type and dimensions;
    • System diagram and control schematic diagram;
    • Special requirements will be resolved through negotiation.

    Three-phase direct-entry meter box

    Three-phase direct-entry meter box

    Product Model and main configuration

    Model Configuration Items Specification Quantity
    BX-J101S Table front configuration Disconnector NH2-100/3P 100A 1
    Table configuration Breaker DZ158-125/3P 80A 1
    BX-J101S Table front configuration Breaker DZ47-100/4P 100A 1
    Table configuration Breaker DZ47-100/4P 100A 1
    Note: Main switch connection line BV16mm² or BV25mm²
    Energy meter connection line BV10mm² or BV16mm²

    Installation Dimensions

    Installation Dimensions

    Wiring Diagram

    Wiring Diagram

    Ordering Instructions

    The parameters in this solution are our company's standard configuration. If customers need our company to provide complete Please provide a specific configuration plan for this product.

    Three-phase direct-entry meter box

    Three-phase direct-entry meter box

    Product Model and main configuration

    Model Configuration Items Specification Quantity
    BX-K102S Table front configuration Disconnector NM1-100A/4300 1
    Table configuration Breaker NM1-225A/3300 1
    BX-KF102S Table front configuration Breaker NM1-100A/3300 1
    Table configuration Breaker NM1-100A/3300 1
    Note: Main switch connection line BV25mm² or BV35mm²
    Energy meter connection line BV16mm² or BV25mm²

    Installation Dimensions

    Installation Dimensions

    Wiring Diagram

    Wiring Diagram

    Ordering Instructions

    The parameters in this solution are our company's standard configuration. If customers need our company to provide complete Please provide a specific configuration plan for this product.

    Single-phase four-household meter box (with host control cabinet)

    Single-phase four-household meter box

    Product Model and main configuration

    Model Configuration Items Specification Quantity
    BX-J401Z Total incoming line Breaker NM1-100H/3300 1
    Outgoing Disconnector NH2-100/1 4
    Incoming line Breaker DZ47-60/2 4
    BX-J402Z Total incoming line Breaker NM1-100H/3300 1
    Outgoing Terminal Blocks Two in and eight out 1
    Incoming line Breaker DZ47-60/2 4
    BX-J403Z Total incoming line Breaker NM1-100H/3300 1
    Outgoing Terminal Blocks Two in and eight out 1
    Incoming line Terminal Blocks Eight in and eight out 1
    Note: Main switch connection line BV16mm² or BV25mm²
    Energy meter connection line BV10mm² or BV16mm²

    Installation Dimensions

    Installation Dimensions

    Wiring Diagram

    Wiring Diagram

    Ordering Instructions

    The parameters in this solution are our company's standard configuration. If customers need our company to provide complete Please provide a specific configuration plan for this product.

    Single-phase eight-household meter box (with host control cabinet)

    Single-phase eight-household meter box

    Product Model and main configuration

    Model Configuration Items Specification Quantity
    BX-K801Z Total incoming line Breaker NM1-225S/3300 1
    Outgoing Disconnector NH2-100/1 8
    Incoming line Breaker DZ47-60/2 8
    BX-K802Z Total incoming line Breaker NM1-225S/3300 1
    Outgoing Terminal Blocks Three in and nine out, one in and nine out 8
    Incoming line Breaker DZ47-60/2 1
    BX-K803Z Total incoming line Breaker NM1-225S/3300 1
    Outgoing Terminal Blocks Three in and nine out, one in and eight out 1
    Incoming line Terminal Blocks Sixteen in and sixteen out 1
    Note: Main switch connection line BV16mm² or BV25mm²
    Energy meter connection line BV10mm² or BV16mm²

    Installation Dimensions

    Installation Dimensions

    Wiring Diagram

    Wiring Diagram

    Ordering Instructions

    The parameters in this solution are our company's standard configuration. If customers need our company to provide complete Please provide a specific configuration plan for this product.

    Frequently Asked Questions (FAQ)

    What are the standard ambient conditions for operating these meter boxes?
    These meter boxes are designed for altitudes not exceeding 2000m, ambient temperatures between -25℃ and +40℃, and relative humidity not exceeding 40% at +20℃. They should be installed in locations without severe vibration, impact, or explosive hazards.
    What ingress protection (IP) ratings can be provided?
    We support multi-level protection ratings including IP20, IP40, IP43, IP54, and IP65, satisfying the installation demands of both indoor and outdoor environments.
    Can the dimensions and structure of the cabinets be customized?
    Yes. Cabinet dimensions can be fully customized based on the technical drawings provided by the customer. The structural type is available in multiple series, including welded, split, and assembled structures.
    What is the difference between JXF and JFF models?
    JXF models are designed for either surface-mounted or concealed installations. JFF models are divided into metal door types and perspective window door types. Both feature sealing rubber strips to prevent rainwater entry.
    How do I order a custom configuration for these meter boxes?
    When ordering, please specify the model, installation method, structural type and dimensions, system diagram, and control schematic diagram. Special configuration plans can be negotiated based on your specific requirements.

    Leave Your Message

    AI Helps Write