Leave Your Message

China JXF Low Voltage Distribution Box Series - Reliable Control Boxes for Power Distribution | Suppliers and Factory

,

Overview

,

Introducing the JXF Control Box, a reliable solution designed for power distribution in three-phase systems. This versatile control box operates at 50Hz and 500V, catering to loads up to 250A, making it suitable for three-phase three-wire, four-wire, and five-wire configurations. Offering essential leakage protection, the JXF Control Box is a product of high-quality manufacturing, ideal for use in various sectors including metallurgy, petrochemicals, healthcare, aviation, residential areas, shopping malls, schools, and urban redevelopment.

,

Boasting a compact design and aesthetically pleasing appearance, this control box ensures both safety and reliability. As a leading product among China suppliers and manufactured in state-of-the-art factories, it meets rigorous quality standards to provide optimal performance in any environment. Choose the JXF Control Box for your power distribution needs and experience unparalleled efficiency and safety.

,

    Model and Definitions

    product-description1

    Use Environment and Conditions

    Altitude not exceeding 2000m;
    The ambient air temperature shall not exceed +40℃ and shall not be lower than -25℃;
    At +20℃, the monthly average relative humidity of the air is no more than 40%;
    A place without severe vibration and impact;
    There are no explosive hazardous areas, and there are no gases or conductive dust in the medium that can corrode metals or damage insulation.

    Structural characteristics

    Multiple series, multiple structures, welded, split, assembled; outdoor, indoor;
    A variety of double-door structures, safe and reliable to use;
    Multi-level protection IP20, IP40, IP43, IP54, IP65; Can meet the needs of different places;
    product-description2

    Dimensions (welded)

    Specification high H(mm) Width W (mm) Deep D(mm) Thickness of iron sheet Structural Feature
    2520/14 250 200 140 1.2

    1.5
    JXF comes in two types: surface mounted and concealed. JFF is divided into two types: metal doors and perspective window doors. The door panels are affixed with sealing rubber strips to prevent rainwater from seeping in. The box is equipped with upper and lower inlet and outlet holes, as well as an installation base. The inlet and outlet holes have been equipped with sealing plates at the factory, and the door opening angle is greater than 90 °. JXF and JFF1 each have 25 specifications, while JFF2 has 18 specifications.
    3025/14 300 250 140
    3025/18 300 250 180
    3030/14 300 300 140
    3030/18 300 300 180
    4030/14 400 300 140
    4030/20 400 300 200
    5040/14 500 400 140
    5040/20 500 400 200
    5040/23 500 400 230
    6040/14 600 400 140
    6040/20 600 400 200
    6040/23 600 400 230
    6050/14 600 500 140
    6050/20 600 500 200
    6050/23 600 500 230
    7050/16 700 500 160
    7050/20 700 500 200
    7050/23 700 500 230
    8060/20 800 600 200
    8060/23 800 600 230
    8060/25 800 600 250
    10080/20 1000 800 200
    10080/25 1000 800 250
    10080/30 1000 800 300
    Note: The cabinet dimensions can be determined based on the drawings provided by the customer.

    Order Cargo Information

    ◆ Please specify when ordering:
    Model;
    Installation method;
    Structural type and dimensions;
    System diagram and control schematic diagram;
    Special requirements will be resolved through negotiation.

    Three-phase direct-entry meter box

    product-description2

    Product Model and main configuration

    Model Configuration Items Specification quantity
    BX-J101S Table front configuration Disconnector NH2-100/3P 100A 1
    Table configuration breaker DZ158-125/3P 80A 1
    BX-J101S Table front configuration breaker DZ47-100/4P 100A 1
    Table configuration breaker DZ47-100/4P 100A 1
    Note: Main switch connection line BV16mm² or BV25mm²
    Energy meter connection line BV10mm² or Bv16mm²
    Installation Dimensions
    Installation Dimensions
    Wiring Diagram
    Wiring Diagram

    Ordering Instructions

    The parameters in this solution are our company's standard configuration. If customers need our company to provide complete Please provide a specific configuration plan for this product.

    Three-phase direct-entry meter box

    product-description5

    Product Model and main configuration

    Model Configuration Items Specification quantity
    BX-K102S Table front configuration Disconnector NM1-100A/4300 1
    Table configuration breaker NM1-225A/3300 1
    BX-KF102S Table front configuration breaker NM1-100A/3300 1
    Table configuration breaker NM1-100A/3300 1
    Note: Main switch connection line BV25mm² or BV35mm²
    Energy meter connection line BV16mm² or BV25mm²
    Installation Dimensions
    Installation Dimensions
    Wiring Diagram
    Wiring Diagram

    Ordering Instructions

    The parameters in this solution are our company's standard configuration. If customers need our company to provide complete Please provide a specific configuration plan for this product.

    Single-phase four-household meter box (with host control cabinet)

    product-description8

    Product Model and main configuration

    Model Configuration Items Specification quantity
    BX-J401Z Total incoming line breaker NM1-100H/3300 1
    Outgoing Disconnector NH2-100/1 4
    Incoming line breaker DZ47-60/2 4
    BX-J402Z Total incoming line breaker NM1-100H/3300 1
    Outgoing Terminal Blocks Two in and eight out 1
    Incoming line breaker DZ47-60/2 4
    BX-J403Z Total incoming line breaker NM1-100H/3300 1
    Outgoing Terminal Blocks Two in and eight out 1
    Incoming line Terminal Blocks Eight in and eight out 1
    Note: Main switch connection line BV16mm² or BV25mm²
    Energy meter connection line BV10mm² or Bv16mm²
    Installation Dimensions
    Installation Dimensions
    Wiring Diagram
    Wiring Diagram

    Ordering Instructions

    The parameters in this solution are our company's standard configuration. If customers need our company to provide complete Please provide a specific configuration plan for this product.

    Single-phase eight-household meter box (with host control cabinet)

    product-description11

    Product Model and main configuration

    Model Configuration Items Specification quantity
    BX-K801Z Total incoming line breaker NM1-225S/3300 1
    Outgoing Disconnector NH2-100/1 8
    Incoming line breaker DZ47-60/2 8
    BX-K802Z Total incoming line breaker NM1-225S/3300 1
    Outgoing Terminal Blocks Three in and nine out, one in and nine out 8
    Incoming line breaker DZ47-60/2 1
    BX-K803Z Total incoming line breaker NM1-225S/3300 1
    Outgoing Terminal Blocks Three in and nine out, one in and eight out 1
    Incoming line Terminal Blocks Sixteen in and sixteen out 1
    Note: Main switch connection line BV16mm² or BV25mm²
    Energy meter connection line BV10mm² or Bv16mm²
    Installation Dimensions
    Installation Dimensions
    Wiring Diagram
    Wiring Diagram

    Ordering Instructions

    The parameters in this solution are our company's standard configuration. If customers need our company to provide complete Please provide a specific configuration plan for this product.

    Frequently Asked Questions (FAQ)

    Q1: What environmental conditions are required for installing these meter boxes?
    A: The installation site should be at an altitude not exceeding 2000m, with ambient air temperatures between -25℃ and +40℃. The monthly average relative humidity must not exceed 40% at +20℃. Additionally, the location must be free from severe vibration, impacts, explosive hazards, and gases or dust that can corrode metals or damage insulation.
    Q2: What ingress protection (IP) ratings are available for these cabinets?
    A: We offer multiple levels of structural protection to suit different locations, including IP20, IP40, IP43, IP54, and IP65. This ensures safe and reliable operations for both indoor and outdoor installations.
    Q3: Can the dimensions of the welded cabinets be customized?
    A: Yes. While we have standard specifications (ranging from 2520/14 to 10080/30), cabinet dimensions can also be custom-designed and manufactured based on the engineering drawings provided by the customer.
    Q4: What structural options are available for the JXF and JFF series?
    A: The JXF series is available in both surface-mounted and concealed structures. The JFF series is divided into metal doors and perspective window doors. All door panels are affixed with sealing rubber strips to prevent rainwater entry, and the box doors have an opening angle greater than 90°.
    Q5: What essential details must be specified when ordering?
    A: When placing an order, please specify the product model, installation method, structural type and dimensions, system diagram, and control schematic diagram. Any special requirements can be resolved through negotiation.
    Q6: Can I request a custom component configuration instead of the standard one?
    A: Yes. The configuration parameters listed in our tables are standard configurations. If your project requires specific breakers, disconnectors, or terminal block layouts, please provide a detailed configuration plan for customization.

    Leave Your Message