The HXGN17-12 Box-Type Fixed AC Metal-Enclosed Ring Network Switchgear, often known as a ring network cabinet, is a high-performance electrical solution operating at a nominal voltage of 12kV and a rated frequency of 50Hz. As one of the leading products from China, this high-voltage switchgear is specifically engineered for three-phase AC ring networks, terminal distribution networks, and industrial power supply systems. It is crucial for effectively receiving and distributing electrical energy while providing essential protection across various installations, including box-type substations.
Manufactured in compliance with GB3906 standards for 3.6~40.5 kV AC metal-enclosed switchgear and control equipment, this product also adheres to international IEC298 standards, ensuring its reliability and quality. The switchgear is equipped with a five-proof interlocking function that significantly enhances operational safety and dependability. Trustworthy suppliers and manufacturers recognize its importance in the power distribution industry, making it a valuable asset for any electrical infrastructure in need.

,

    Standards

    • GB 3906-2006 "AC Metal-Enclosed Switchgear and Controlgear for Rated Voltages from 3.6 kV to 40.5 kV"
    • IEC 60298-1990 "Metal-Enclosed Switchgear and Controlgear for Rated Voltages Above 1 kV and Up to 52 kV"
    • GB/T 11022-2011 "Common Technical Requirements for High-Voltage Switchgear and Controlgear Standards"

    Model and Definitions

    Model and Definitions Diagram

    Conditions of Use

    • Ambient Temperature: Upper limit +40℃, Lower limit -25℃;
    • Altitude: Not exceeding 1000m;
    • Relative Humidity: Daily average not exceeding 95%, Monthly average not exceeding 90%;
    • Locations free from fire, explosion hazards, and severe vibrations;
    • Surrounding air must not contain corrosive or flammable gases, water vapor, or conductive dust, avoiding significant contamination.

    Major Technical Specifications

    No. Items Units FN12-12 FZN25-12
    1 Nominal Voltage kV 12
    2 1min Power Frequency Withstand Voltage kV Ground and phase-to-phase 42; Isolation Break Point 48
    3 Lightning Impulse Voltage (Peak) Ground and phase-to-phase 75; Isolation Break Point 85
    4 Rated Frequency Hz 50
    5 Load Switch Rated Current A 630
    6 Rated Current Switching Life Times Not less than 100
    7 Breaking Capacity of No-load Transformer kVA 1250
    8 Rated Thermal Stability Current kA/s 20/4; Ground switch 20/2
    9 Rated Dynamic Stability Current (Peak) kA 50
    10 Rated Circuit Making Current (Peak) 50
    11 Fuse Rated Current A 125
    12 Composite Apparatus Rated Transfer Current A 870
    13 Rated Short-circuit Breaking Current kA 20
    14 Compatible Fuse Model S □ LAJ-12
    15 Machinery Service Life Times 2000 10000
    16 Auxiliary Circuit 1min Power Frequency Withstand Voltage kV 2
    17 Electric Operating Mechanism Working Voltage V AC/DC 220; 110
    18 Level of Protection IP2X

    Structural Features

    • The fully assembled structure is lightweight and aesthetically pleasing, allowing for arbitrary combinations and installations, facilitating infinite expansion.
    • It can be equipped with the FN12-12 type pneumatic Load Switch, Composite Apparatus, or the FZN25-12 type vacuum Load Switch, Composite Apparatus. It is compact, maintenance-free, features a three-phase linkage structure, and has a distinct Isolation Break Point.
    • The installation method for the Load Switch and Composite Apparatus is flexible, allowing for left-side, right-side, upright, and inverted installations (FZN25 cannot be inverted).
    • It supports both manual and electric operation and can have remote control capabilities.
    • Equipped with a complete and reliable mechanical linkage and interlocking device, it fully meets the "five prevention" functions. When the Load Switch is closed, the grounding switch cannot close, and the front door cannot be opened; when the Load Switch is opened, the grounding switch can close, and the front door can be opened when the grounding switch is closed; when the grounding switch is closed, the Load Switch cannot close, but the front door can be opened; when the grounding switch is opened, the Load Switch can open and close, and the front door cannot be opened; when the cable enters from below, if there is power at the entry, regardless of whether the Load Switch is in the closed or open position, the electromagnetic lock controls the front door, preventing it from being opened (except for emergency unlocking with a special key).
    • The Load Switch uses interlocking protective insulated valves or transparent insulated covers to shield live contacts, ensuring personal safety.
    • It employs front operation and maintenance, reliably wall-mounted.
    • The front door is equipped with a viewing window to clearly observe the working conditions of the components inside the cabinet.

    External Dimensions

    External Dimensions Specification Diagram

    Ordering Notes

    When placing an order, the following technical information must be provided:

    • Main wiring scheme number, purpose, and single-line system diagram, Nominal Voltage, Rated Current, Rated Short-circuit Breaking Current / layout of the distribution room and arrangement configuration diagram of the switch cabinet, etc.;
    • Requirements for the control, measurement, and protection functions of the switch cabinet, as well as the requirements and schematic diagrams for other locking and automatic devices;
    • Model, specifications, and quantity of the main electrical components in the switch cabinet;
    • If the switch cabinet is used in special environmental conditions, this should be detailed during the order placement.

    Frequently Asked Questions (FAQ)

    What standards do these switchgears comply with?
    These switchgears comply with GB 3906-2006 (AC Metal-Enclosed Switchgear for 3.6 kV to 40.5 kV), IEC 60298-1990 (Metal-Enclosed Switchgear Above 1 kV and Up to 52 kV), and GB/T 11022-2011 (Common Technical Requirements for High-Voltage Switchgear Standards).
    What are the environmental limits for using this switchgear?
    The ambient temperature must be within +40℃ (upper limit) and -25℃ (lower limit). The altitude should not exceed 1000m. The daily average relative humidity must not exceed 95% (monthly average ≤ 90%). It must be installed in locations free from fire, explosion hazards, severe vibrations, and corrosive or flammable gases.
    What kinds of load switches can be installed in the cabinet?
    It can be equipped with the FN12-12 type pneumatic Load Switch / Composite Apparatus, or the FZN25-12 type vacuum Load Switch / Composite Apparatus. Both feature a three-phase linkage structure and a distinct Isolation Break Point.
    What safety mechanisms prevent improper operation?
    It features a complete mechanical linkage and interlocking device meeting the "five prevention" functions. For example, when the Load Switch is closed, the grounding switch cannot close, and the front door remains locked. Additionally, electromagnetic locks control access to the front door if the incoming cable is live.
    What is the mechanical service life of the FN12-12 and FZN25-12 models?
    The FN12-12 model has a mechanical service life of 2,000 operations, while the FZN25-12 model offers an extended service life of 10,000 operations.
    What information is required when placing an order?
    You need to provide the main wiring scheme, purpose, single-line system diagram, nominal voltage, rated current, control and protection requirements, models/specifications of main electrical components, and details of any special environmental conditions if applicable.