Product Features

,

This innovative product features prefabricated, touchable silicone rubber cable terminals that are completely sealed and insulated, ensuring a maintenance-free operation while prioritizing personal safety. The compact structure boasts an appealing design, highlighted by a durable double-layer stainless steel body that provides over twenty years of service life. One of its standout advantages is the ability to conduct regional power outage maintenance without disrupting the main network, significantly minimizing the impact of power outages. Additionally, it can accommodate one or multiple SF6 Load Switches, offering flexible wiring methods with branch outgoing lines capable of supporting up to 8 circuits. Optional components such as surge protectors, short-circuit fault indicators, and current-limiting fuses are readily available to cater to diverse user needs. As a reliable choice for businesses in China, this product exemplifies the quality and innovation provided by leading suppliers and factories in the industry.

,

    Model and Definitions

    Model and Definitions of DFW Cable Branch Box

    DFW Technical Parameters

    No. Items Parameters
    1 Nominal Voltage 12kV
    2 Rated Currency 630A
    3 Power Frequency Withstand Voltage (Phase to Ground) 42kV/min
    4 Lightning lmpulse Voltage 75kV
    5 Rated Breaking Current 630A
    6 Rated Short-circuit Making Current(Peak Value) 50kA
    7 Rated Short-time Withstand Current 25kA/4S
    8 Rated Peak Withstand Current 50kA
    9 Rated Peak Withstand Current 45A
    10 Rated Breaking Capacitive Current 16A
    11 Full Load Breaking Time >100
    12 Mechanical Operation Time for Opening and Closing 2000

    External Schematic Diagram

    External Schematic Diagram of DFW Cable Branch Box

    Basic Structure

    Basic Structure Layout 1Basic Structure Layout 2

    Technical Requirements

    The inner side of the brick wall is to be sealed with a 1:3 cement mortar mix and treated for waterproofing.
    Beam penetrations should use φ6 concrete operations.
    The foundation channel steel must undergo anti-corrosion treatment after fabrication.
    After the installation of the branch box is completed, the area around the base should be sealed with cement.
    Waterproof measures must be taken at the manhole entrance.
    Grounding electrodes should be pre-embedded in the foundation, with grounding resistance meeting the requirements set by the power department.

    Ordering Instructions

    The product model and any special requirements from the user can provide a one-time diagram.
    The standard cross-sections for incoming and outgoing lines and branch cables.
    The quantity of optional surge protectors and short-circuit fault indicators.

    Frequently Asked Questions (FAQ)

    What is the nominal voltage and rated current of the DFW cable branch box?

    The DFW cable branch box operates at a nominal voltage of 12kV and has a rated current of 630A.

    What are the short-circuit withstand capabilities of this equipment?

    The equipment has a rated short-time withstand current of 25kA for 4 seconds (25kA/4S) and a rated peak withstand current of 50kA.

    What waterproofing requirements must be met during installation?

    The inner side of the foundation brick wall must be sealed with a 1:3 cement mortar mix and waterproofed. Additionally, waterproof measures must be implemented at the manhole entrance.

    How should the foundation and base structure be prepared?

    The foundation channel steel needs anti-corrosion treatment after fabrication. After the installation of the branch box is completed, the area surrounding the base must be sealed with cement.

    What grounding specifications are required?

    Grounding electrodes should be pre-embedded in the foundation, and the overall grounding resistance must comply with the regulations and requirements of the power department.

    What details need to be provided when placing an order?

    When ordering, please provide the product model, any special requirements (for one-time diagrams), standard cross-sections for incoming/outgoing/branch cables, and the desired quantity of optional surge protectors and short-circuit fault indicators.