Leave Your Message

40.5kV Combined Substation: Reliable Outdoor Switchgear by China Suppliers for Factories and Urban Use

,

Product Overview

,

Our outdoor complete switchgear is designed for both the 40.5kV and 12kV sides, making it an ideal choice for urban areas, towns, factories, oil fields, and large construction sites in China. This advanced electrical equipment is engineered to efficiently receive, convert, and distribute electrical energy. Featuring a compact design and high reliability, it ensures easy installation and low operational costs. With a high level of automation, our switchgear guarantees safety and dependability, making it a top choice among suppliers and factories seeking quality electrical solutions.

,

    Model and Definitions
    Substation Model and Definitions
    Application Conditions
    Altitude: ≤1000m; Ambient temperature: -15℃ to +40℃;
    Temperature: Maximum monthly average temperature +30℃, maximum annual average temperature +20℃;
    Relative Humidity: Daily average not exceeding 95%, monthly average not exceeding 95%;
    Wind speed: Wind speed not exceeding 34m/s;
    The installation site should be free from severe shocks, serious pollution, and chemical corrosion, as well as conductive dust and explosion hazards. If normal application conditions cannot be met, please consult with our company for solutions.
    Structural Features
    The overall structure of the substation consists of two high-voltage switch rooms on the 40.5kV side and the 12kV side, a relay protection room, and a transformer. The outer shell of the high-voltage switch room and relay protection room can be made of stainless steel plates, steel plates, or composite boards. Stainless steel structures possess exceptional corrosion resistance and good mechanical strength. Each component of the steel plate structure undergoes special anti-corrosion treatment. Meanwhile, composite boards feature bright colors, aesthetic appeal, and thermal insulation properties. The transformer is located between the high-voltage switch rooms on the 40kV side and the 12kV side, directly installed on the foundation, making it convenient for both users and manufacturers to install.
    Frequently Asked Questions (FAQ)
    What is the maximum installation altitude for the substation?
    The standard installation altitude for the substation should be less than or equal to 1000 meters (≤1000m).
    What are the ambient temperature limits for this equipment?
    The ambient temperature range is -15℃ to +40℃, with a maximum monthly average of +30℃ and a maximum annual average of +20℃.
    What materials can be used for the substation's outer shell?
    The outer shell of the high-voltage switch room and relay protection room can be constructed using stainless steel plates, steel plates, or composite boards.
    How is the transformer installed within the substation structure?
    The transformer is positioned between the high-voltage switch rooms on the 40kV side and the 12kV side, and is directly installed on the foundation for easy setup.
    What environmental hazards must be avoided at the installation site?
    The site must be kept free from severe shocks, serious pollution, chemical corrosion, conductive dust, and explosion hazards.
    What is the maximum wind speed tolerance for this substation?
    The substation is designed to withstand ambient wind speeds not exceeding 34m/s.

    Leave Your Message

    AI Helps Write